Commissioning
19
Checking emergency release
With sectional doors, or doors with ceiling guides, you have the
option of activating the backjump with DIP switch 6 in order to
offload the operator and door mechanisms.
• Close the door with the drive.
• Pull the emergency release (N) 1x.
If the emergency release cannot be operated, loosen the end switch
(V) and move it in direction (1).
• Open the door with the drive and close it again. Test the emergency
release again.
Checking force setting
Whenever the door is opened or closed, the control unit compares the
memorised force setting with the force actually needed and automatically
adjusts the memorised setting accordingly when the given final travel
position is reached.
For checking details see 'Maintenance and Care' section.
Programming of remote control
Prior to the initial programming of the hand-held transmitters,
clear the memory of the radio receiver.
Clearing radio receiver memory
• Press and hold the programming key (1).
- After 5 seconds, the LED (3.1 or 3.2) flashes. After another
10 seconds, the LED is constantly on (3.1 or 3.2).
- After 25 seconds, all LEDs are on (3.1 + 3.2).
• Release the programming key (1). All channel data has been
deleted.
Programming the radio transmitter
• Press the programming key (1)
- 1x for channel 1; LED (3.1) is on
- 2x for channel 2, LED (3.2) is on
- If no other code signal is transmitted within 10 seconds, the radio
receiver switches to standard operation.
- Aborting programming: repeatedly press the programming key (1)
until all LEDs are off.
• Press and hold desired hand-held transmitter key (5) until the LED
(3.1 / 3.2) is off (depending on the selected channel).
• The LED is off - the programming process is completed.
The hand-held transmitter has transmitted the radio codes to the
radio receiver.
Continue with programming the other hand-held transmitters. To do this,
repeat the above steps. The maximum number of memory blocks is 112
per radio receiver.
Attaching instruction label
• Attach the instruction label for the operation of the emergency
release to the emergency release rope.
Attaching warning sign
• Attach the warning signs (text + triangle sign) at a position where
they are clearly visible, e.g. beside the push-button (warning triangle)
and on the door leaf (text + warning triangle).
1.
1.
2.
2.
1.
1.
2.
2.
Kommentare zu diesen Handbüchern