Marathon Sprint Series Betriebsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
Installation duo
16
Position, align and the secure control housing using 4 screws (1).
Supplied components 2 plugs, 2 screws.
Slot the control board (1) into terminal bar (2) and slide it into the
housing.
Touch the control unit (3) only at its edge!
Do not touch the electronic components!
Install the control unit (3). Mount the lamp hood (2) and tighten the
screws (1).
Installing the socket Outlet
Socket outlet may only be installed by a qualified electrician.
Protect socket with a fuse (16 A slow-blow).
Observe all applicable regulations (e.g. VDE, etc.)!
Install socket (1) on ceiling at a distance of approx. 0.5 meters to the
control unit housing (2).
Install and connect the connection cable from the socket outlet (1) to
the mains power supply. Do not plug the connector into the socket
outlet yet!
30
H
30 C30
1
3
2
29
29
2
1
3
28
27
28
2
1
2
3
4
5
6
3 4
1
2
3
4
5
6
5
5
7
7
8
8
4
4
6
6
3
3
2
2
1
1
O
N
ON
D
IP
DIP
2
2
3
3
4
4
5
5
6
6
1
1
1
27
3
4x
Installing and connecting and
additional push-button
Only necessary if a further push-button is required in addition to
the one already installed (1).
Use the contact only for potential-free normally closed contacts.
External voltage may damage or even destroy the control unit.
Position the push-button in such a way that the operator can see
the door, while he/she is not inside the operating area of the
door.
Never run the push-button cable along a power cable as this can cause
the control unit to malfunction.
Install push-button (1) in an appropriate, easily accessible location in
the garage. Minimum height from the floor: 1,6 m
Install button cable (2) in garage. Connect end of cable to push-but-
ton (1).
Only hold outside edge of control board (1)! Do not touch the
electronic components!
Undo screw (3) on control unit housing (6), remove light diffuser (4).
Connect the key switches (potential-free NO contact), if any, to
the terminals 5 + 6.
Lift the control board (1) from the housing (8) and disconnect it from
the terminal bar (2).
Connect the push-button cable (3) to terminals 5 + 6 of the terminal
bar (2).
Slot the control board (1) into terminal bar (2) and slide it into the
housing (8).
Mount the lamp hood (7) and tighten the screw (4).
32
32
7
4
8
3
2
1
2
3
4
5
6
1
2
3
4
5
6
5 6
5
5
7
7
8
8
4
4
6
6
3
3
2
2
1
1
ON
ON
DIP
DIP
2
2
3
3
4
4
5
5
6
6
1
1
1
31
1,6m
2
1
4
3
6
5
C31
1,6m
2
1
A31
`
1
3
A
B
`
½
B31
`
,1
2
6
`
m
°
1,6m
`
,1
2
6
`
m
°
2
`
,1
2
6
`
m
°
1
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 34 35

Kommentare zu diesen Handbüchern